HOW TO USE
IN USE DoRAON
Insert chemicals in proper amount into the chemical bottle and turn its cap to the right.
Connect the chemical bottle with the chemical to its body.
(Connect them until the chemical bottle separation/connection button connects to the body with “ddak” sound)
Turn the chemical control lever of the chemical bottle to the right in order to place the chemical bottle valve in the close position.
Plug the power cord at the outlet.
While moving the slide controller to the “Strong” Position, turn the chemical control lever to the left to open the valve.
(For Bure 3 and Bure 3 New, place the power switch “IN” Position.)
IN FINISH DoRAON
Turn the chemical control lever of the chemical bottle to the right to close the chemical control valve.
Place the slide controller in the “Weak” position.
Wait for about 4-5 seconds until the motor stops.
Push the Air release push button (on the cap of the chemical bottle) until all the air is released.
Separate the chemical bottle from the body. (It is possible to remove the chemical bottle by pushing the separation button.)
While moving the slide controller to the “Strong” Position, turn the chemical control lever to the left to open the valve.
(When spraying is completed, it is necessary to operate the body until the air is released.)
Keep the chemical bottle connected with the body.
IN AIR-SPRAYING AND CLEANING
Separate the chemical bottle from the body. (It is possible to remove the chemical bottle by pushing the separation button.)
Turn the nozzle cap for spraying to the left to separate from the body.
Assemble the wrinkle hose to the nozzle cap for cleaning and then to the body.
Place the slide controller in the “Strong” position and spray air to the place you want.
*After air spraying and cleaning, it is necessary to replace the nozzle cap for cleaning with one for spraying. -> If you use the nozzle cap for cleaning, it is impossible to clean.
DoRAON USER NOTE
- This product is used only for 110V.
- Protection degree: IPx4
- In replacing a fuse, it is necessary to use only the proper fuse.
If you use one other than the proper fuse, fire or error can occur. - In providing and mixing chemicals, you should follow the corresponding guidelines.
- In handling and spraying toxic chemicals, you should wear protective equipment.
- Only the person with sufficient related knowledge should operate the machine.
- Don’t put flammable agents (gasoline, thinner, kerosene, diesel and so on) into the chemical bottle.
- It is necessary to push the air release push button until the air is completely released after use. Be cautious about firearms and shock.
- It is necessary to wash the chemical bottle with water and to spray water into it for 30~60 seconds after use. (Otherwise the product can be blocked or damaged due to the remaining chemical.)
- The machine is wet or sinks into water, it should not be supplied with power.
In this case, you should contact our service center. It can cause fire or electric shock. - It is necessary to look around and to be careful so as not to spray others in spraying chemicals. It should be kept in the places where children can’t approach.
- Its users should not be release or modify the product as they want.
It can cause errors and malfunction to the product and lead to fire or electric shock. (The product released or modified can’t receive AS.)
DoRAON SPECIFICATION
Particle Size | 10~50μm (Adjustable) |
---|---|
Spray Range | 16.6~32ft (Adjustable) |
Capacity | 3L |
Dimensions | 550 x 160 x 250mm (L x W x H) |
Weight | 6.3 LB |
Motor Power | 1,250W |
Length of Wire | 20ft |
Input Power | 110V |
Color | Gray |